What Is UDI?

The Unique Device Identification (UDI) system is an FDA requirement that every medical device carry a unique identifier that allows the device to be tracked throughout its distribution and use in healthcare settings. It was introduced under 21 CFR Part 830 and has been phased in since 2014, now applying to virtually all medical devices.

A UDI consists of two parts:

What Is GUDID?

The Global Unique Device Identification Database (GUDID) is the FDA's publicly accessible database of device identifier information. All labelers required to comply with UDI must submit device information to GUDID before or at the time of placing the device into commercial distribution in the U.S.

Who Must Comply?

UDI labeling and GUDID submission requirements apply to:

UDI Phase-In Compliance Dates (Historical Reference)

  • Class III devices: September 24, 2014
  • Class II devices: September 24, 2016
  • Class I devices: September 24, 2018 (label only) / September 24, 2020 (GUDID)

All classes are now fully subject to UDI requirements.

Choosing an FDA-Accredited Issuing Agency

You must obtain your UDI from one of the FDA-accredited issuing agencies. Currently three are accredited:

Most manufacturers use GS1 due to its global adoption. You apply for a GS1 Company Prefix, which is then used to generate unique GTINs for each device version/model.

GUDID Submission: Step-by-Step

  1. 1
    Register for a GUDID account Go to the GUDID portal (accessgudid.nlm.nih.gov) and register. You will need your establishment registration number and FDA credentials.
  2. 2
    Obtain your UDI from an accredited issuing agency Apply with GS1, HIBCC, or ICCBBA. This involves paying a membership fee and receiving your company prefix or labeler code.
  3. 3
    Populate the required device attributes GUDID requires extensive data for each DI, including device description, MRI safety, sterility, implantable status, single-use designation, and dimensions.
  4. 4
    Submit and receive DI record Submit via the GUDID web interface or bulk upload. Once submitted and validated, your DI record is publicly searchable.
  5. 5
    Apply UDI to device label The UDI must appear on the device label in both human-readable form (HIBC or linear bar code) and machine-readable form (typically a 2D Data Matrix barcode).

Common GUDID Submission Errors

✅ UDI compliance is an ongoing obligation. Any change to device labeling that affects the DI (such as a new version, size, or packaging change) may require a new DI and updated GUDID submission.
Need help with this? Regovant handles the entire FDA registration process for you. View our services →